BPXJH - STYCAST 1269A, PART A

  • MSDS: BPXJH
  • Manufacturer: EMERSON AND CUMING INC
  • Product Name: STYCAST 1269A, PART A
  • National Stock Number: 8030-00N034085
Product Identification

Product ID:STYCAST 1269A, PART A
MSDS Date:03/24/1989
FSC:8030
NIIN:00N034085
MSDS Number: BPXJH

Responsible Party
EMERSON & CUMING INC
77 DRAGON COURT
WOBURN, MA 01888
US

Emergency Phone: 617-935-4850 OR 617-938-8630

Info Phone: 617-828-3300

Preparer: DAVID HAAS

Cage: DO244

Contractor
EMERSON & CUMING INC DIV/W R GRACE CO
AUOBURN, MA 01888 US

Telephone: (617) 935-4850 OR (617) 938-8630

Cage: DO244

Ingredients

W/SAND, VERMICULITE OR OTHER ABSORB MATL.

RTECS: 9999999ZZ


W/SOAP WATER & RINSE. PVNTS RINSES FROM ENTERING

RTECS: 9999999ZZ


ARE CLASSIFIED AS CHEM WASTE, & MUST BE DISPOSED OF

RTECS: 9999999ZZ


EPOXY RESIN

Fraction By Weight: 100%


INTO DRAINS, SEWERS & OTHER WATERWAYS. SHOVEL OR

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: INHALATION OF VAPORS AT
ELEVATED TEMPERATURES MAY CAUSE IRRITATION. EYE:IRRITATION UPON
DIRECT CONTACT. SKIN:IRRITATION UPON DIRECT CONTACT. PROLONGED
EXPOSURE MAY RESULT IN SKIN SENSITIZATION. INGEST:HARMFUL IF
SWALLOWED. CHRONIC:ALTHOUGH THE SIGNIFICANCE IS UNKNOWN, THE EPOXY
RESIN IN THIS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:PRODUCT HAS BEEN SHOWN TO BE MUTAGENIC
IN SOME MICROBIAL TESTS, BUT HAS FAILED TO SHOW MUTAGENICITY IN
OTHERS. CHROMOSOMAL ABERRATIONS WERE OBSERVED IN CULTURED RAT LIVER
CELLS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING
DIFFICULT; GIVE ARTIFICIAL RESPIRATION IF NOT BREATHING. GET
IMMEDIATE MEDICAL ATTENTION. EYE:IMMEDIATELY FLUSH W/WATER FOR AT
LEAST 15 MINS. GET ME DICAL ATTENTION. SKIN:REMOVE CONTAMINATED
CLOTHING. WASH AFFECTED AREA W/WATER. INGEST:DILUTE W/WATER. GET
IMMEDIATE MEDICAL ATTENION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:390F,199C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM & WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:TOXIC VAPORS MAY BE EVOLVED UPON EXPOSURE
TO HEAT OR OPEN FLAME.

Accidental Release

Spill Release Procedures:SMALL:WIPE UP OR ABSORB W/VERMICULITE OR OTHER
ABSORB MATL. COLLECT WASTE IN SEALED CONTRS. SCRUB AREA W/SOAPY
WATER & RINSE. PVNTS RINSES FROM ENTERING DRAINS OR OTHER
WATERWAYS. SPILLED MATL & WATER RINSES ARE CLASSIFIED AS CHEM
WASTE, &(SUP DAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY PLACE; KEEP REMOVED
FROM ANY HEAT OR OPEN FLAME. KEEP CONTAINER CLOSED WHEN NOT IN USE.
Other Precautions:AVOID SKIN & EYE CONTACT.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:GOOD GENERAL WORKPLACE VENTILATION IS RECOMMENDED. PROVIDE
SPECIAL VENTILATION AT ELEVATED TEMPERATURES.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MATL TO AVOID:& MERCAPTANS. RXN W/CURING AGENTS IF EXOTHERMIC; SMOKE OR
TOX FUMES MAY BE EVOLVED IF HEAT OR RXN BECOMES EXCESSIVE DUE TO
HIGH CURING TEMPS OR CURING OF LARGE MASSES OF MATL. SPILL PROC
:MUST BE DISPOSED OF I/A/W CURRENT LOC,STATE & FED REGS. LGE:DIKE
AREA TO CONTAIN SPILLED MATL & TO PVNT RUNOFF (ING 2)

Chemical Properties

HCC:N1
Vapor Pres:<1 @ 25C
Spec Gravity:1.20 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS TO SLIGHTLY YELLOW LIQUID.
Percent Volatiles by Volume:<1(WT)

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, AMINES, AMIDES, STRONG LEWIS OR MINERAL ACIDS,
THIOSULFATES, CARBOXYLIC ACIDS, ALCOHOL & (SUPP DATA)
Stability Condition to Avoid:STORAGE IN OPEN CONTRS, EXPOS TO HEAT &/OR
OPEN FLAME, UNCONTROLLED MIXING W/(OR EXPOS TO) INCOMPATIBLE
SUBSTANCES.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE &
OXIDES OF NITROGEN.

Disposal

Waste Disposal Methods:SPILLED MATERIAL & WATER RINSES ARE CLASSIFIED
AS CHEMICAL WASTE & MUST BE DISPOSED OF IN ACCORDANCE W/CURRENT
LOCAL, STATE & FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.